Alstom Voltage / frequency Protection relay AGILE Micom P94VB

SKU: GE_254 Categories: ,

ALSTOM VOLTAGE FREQUENCY PROTECTION RELAY AGILE MICOM P94VB

Technical Specification

• Type Numerical Relay

• Protection Type Frequency

Relay Protections : Under voltage, Over voltage, residual over voltage, negative sequence over voltage, under and over frequency, df/dt, Master trip, DC supply Supervision

Event, Fault and Disturbance Recording

Ansi Codes : 27,59,59N, 47,81O,81U,81df/dt,86,80 DI / DO : 8 / 8

Communication Port : USB Front & RS485 Rear / RJ45 / FO

Protocol : Modbus / IEC103 / COURIER / IEC61850 CT / PT : 0/ 4

Auxiliary Supply : 24-250VDC/AC

PT Supply : 110VAC

Applications include distribution and industrial networks, transformer incomer feeders.

4 stage voltage, 9 stage frequency protection.

Compact withdrawable 20TE case with high I/O density.

Serial and Ethernet protocols,

including IEC 61850 Ed. 2, Modbus , DNP3, IE60870-5-103.

Cyber Security.

P40 Agile P14N, P14D, P94V

P40 Agile Feeder Management

The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimized using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.

Agility and Versatility

MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems.

Key Benefits

  • Comprehensive current, voltage, power and frequency protection
  • Multi-stage independent protection elements, customizable curves
  • Universal power supply, binary input ratings and 1A/5A CT – avoids order options
  • Records up to 2048 events, graphical logic engine, distance-to-fault location
  • Two stage circuit breaker failure and breaker condition monitoring
  • Switchgear supervision including CT/VT, DC supply, full ‘H7’ trip circuit supervision
  • Substation communications including IEC 61850, serial and concurrent protocols
  • Compact, withdrawable design for reduced space applications
  • Eco designed with Product Environmental Profile (PEP), no resident battery

Reviews

There are no reviews yet.

Be the first to review “Alstom Voltage / frequency Protection relay AGILE Micom P94VB”

Your email address will not be published. Required fields are marked *